Tiny Scan 402 Release notes

DRAFT FOR REVIEW

TS402 release notes

Updates arrive through Setup → Software Update on the TS402, or Check For Update on its About web page. Nothing installs unless you choose YES.

Where things stand (29 Nov 2026, 3:06 PM CT)

ItemStatus
Newest software02.04.02 (build 4): on the test (bench) channel, installed and confirmed on the bench unit
Update channel in usebench (test units only). The pilot and stable (customer) channels aren't used yet.
Remote update, start to finishWorking Check, ask Yes/No, signed download, install, test, automatic undo. Last two updates installed from the TS402 screen in 74 and 81 seconds.
Automatic undo (rollback)Proven Build 1 failed its self-test on 28 Nov and the unit went back to its previous software by itself.
Reboot with new softwarePassed two restart tests (28 Nov)
Deliberate broken-update testTo do needs Timothy's OK
Power-pull test during an updateTo do at the shop
Real-engine test (CAN and K-line)Planned Monday at the shop
Save the update work in the code archive (git)Waiting for Timothy's OK
Build 5Proposed see Coming next

02.04.02 · build 4 · 29 Nov 2026

Installed and confirmed

02.04.01 · build 3 · 28–29 Nov 2026

Installed and confirmed (later replaced by build 4)

02.04.00 · build 2 · 28 Nov 2026

Installed and confirmed (later replaced by build 3)

02.04.00 · build 1 · 28 Nov 2026

Failed its self-test, undone automatically

02.03.02 · factory software

The software the bench unit started with. It's kept read-only on every unit as the last-resort fallback.

Coming next: proposed build 5

Not built yet These need Timothy's OK.

  1. LEFT/RIGHT arrows on YES/NO questions. RIGHT picks YES and LEFT picks NO on Software Update, Reset Defaults and Clear DTCs. UP/DOWN still work.
  2. Message screens close by themselves after about 60 seconds, including UPDATE DONE.
  3. "Already running" waits and carries on: it re-checks every 5 seconds and continues when the other update finishes.
  4. Step log: each update step (check, answer, YES, start, done) is written to the unit's log for easier support.
  5. Better remote view of the update screens and button presses, for support.
  6. Known issues from the user guide (pick which to include):
    • Quick Status shows "---" instead of live values.
    • Trouble-code descriptions say "Not available".
    • Setup → Units and the I/M button are separate settings, and units reset to °F/PSI on restart.
    • Reset Defaults only resets the units.
    • The "Technical Manual" on the unit is the old October manual; replace it with the new user guide PDF.